A take-up unit combines a mounted bearing with a slotted cast iron housing that slides along a frame rail driven by an adjusting screw. The slot travel (N2 dimension) allows the bearing centreline to be moved after installation to tension a belt, chain, or timing drive without removing the shaft. Once the correct tension is set the housing is locked by tightening the frame bolts through the slot. The UC insert bearings used in standard and medium duty take-up units are interchangeable with the equivalent pillow block (UCP200/UCP300), 4-bolt flange (UCF200/UCF300), and 2-bolt oval flange (UCFL200/UCFL300) housings for the same bore size — one insert type across all mounting formats on the same machine.
Setscrew Locking Take Up Units
Dual 120° setscrew with wide inner ring UC insert — bidirectional, standard operating speeds. Three duty ratings cover the full load range. The standard UCT200 and wider-slot UCST200 use the same UC insert and are interchangeable with pillow block and flange units for the same bore; UCTX00 and UCT300 step up to higher-rated inserts for elevated belt tensions.
Eccentric Collar Locking Take Up Units
Self-tightening collar that grips progressively under unidirectional shaft rotation. On conveyors and drives that run in one direction continuously, the eccentric collar provides more reliable long-term shaft retention than setscrew under sustained belt tension and frame vibration. Take-up frame dimensions match UCT200 for equivalent bore sizes — insert-only upgrade without changing the frame.
Concentric Collar Locking Take Up Units
360° uniform shaft contact with no eccentric mass — fully bidirectional and suitable for high-speed drives. Releases symmetrically in both directions: correct for reversing conveyors, servo-controlled tension systems, and any take-up position where the drive jogged or reversed during maintenance.
Adapter Sleeve Locking Take Up Units
1:12 tapered bore with H-series adapter sleeve — no shaft surface damage on installation or removal. In take-up applications this matters especially because the shaft is periodically released and retightened as belt tension is adjusted: repeated setscrew tightening at the same position progressively marks the shaft, while the adapter sleeve releases and re-locks without any shaft surface contact.
Understanding Take-Up Frame Dimensions
Take-up units introduce several dimensions not found in pillow block or flange unit tables. Understanding them is essential for frame design and tensioning calculation.
| Dimension | Name | Description |
|---|---|---|
| N1 | Slot width | The narrow dimension of the slot hole that the frame bolt shank passes through. The housing slides along the bolt inside this slot. |
| N2 | Slot arc length (travel) | Total housing travel available for tensioning adjustment. The tensioning screw moves the housing through this range. UCT300 range: 36 mm (UCT305) to 80 mm (UCT328). |
| L | Overall frame length | Total length of the take-up housing including the slot. Used for machine frame cutout and clearance design. |
| L1 | Housing width across slots | Width of the bearing housing body measured across the two slot centres. Used to determine the frame rail spacing. |
| L2 | Slot centre spacing | Centre-to-centre distance between the two slots along the frame rail axis. |
| L3 | Housing body length | Length of the bearing housing body (not including the slot extensions). Used for clearance to adjacent drive components. |
| H / H1 / H2 | Heights | H = total frame height. H1 = bearing centreline height above base. H2 = housing upper profile height. Used for frame rail height and clearance above the mounting surface. |
| A1 | Slot body width | Width of the slot opening in the housing body. UCST200 has a wider A1 than UCT200 to provide more spanner clearance at the frame bolt head during tensioning. |
Series Selection Matrix
Identify the correct series by locking mechanism, duty rating, and bore range. Click the series name to view the full specification table.
| Series | Duty | Locking | Direction | Bore | Key Differentiator |
|---|---|---|---|---|---|
| UCT200 | Standard | Setscrew | Bidirectional | 12–90 mm | Most widely used take-up · UC insert interchangeable with UCP200/UCF200/UCFL200 · UCWT compact variant |
| UCST200 | Standard | Setscrew | Bidirectional | 12–60 mm | Wider A1 slot for bolt-head spanner access in restricted-access frame positions |
| NAT200 | Standard | Eccentric collar | Unidirectional | 12–85 mm | Self-tightening under rotation · more secure than setscrew under sustained vibration · unidirectional only |
| UET200 | Standard | Concentric collar | Bidirectional | 20–60 mm | 360° bidirectional · no imbalance mass · reversing drives and high-speed take-up positions |
| UKT200+H | Standard | Adapter sleeve | Bidirectional | 20–75 mm | No shaft surface damage · safe for repeated tensioning adjustments · HS/HA/HE sleeve variants |
| UCTX00 | Medium | Setscrew | Bidirectional | 25–85 mm | Heavier housing · higher-rated UCX insert · when UCT200 L10 life is insufficient under belt tension |
| UCT300 | Heavy | Setscrew | Bidirectional | 25–140 mm | Maximum take-up load capacity · UC300 insert · metric bore only · UCT328=83.2 kg, N2=80 mm |
Frequently Asked Questions
Ready to Order?
Provide shaft diameter, bore type (metric or inch), drive direction, required slot travel (N2), duty rating, and quantity. New-client samples available at sample pricing. Multi-model orders from USD 1,500 accepted. Engineering drawings required before order confirmation — catalogue dimensions for reference only.